On The Job: New Mexico

  On Friday, June 11, 2010, a two-alarm fire destroyed an abandoned meat-packing plant in Bernalillo County, NM. The fire caused the evacuation of 250 workers and residents from neighborhoods around the facility.


  On Friday, June 11, 2010, a two-alarm fire destroyed an abandoned meat-packing plant in Bernalillo County, NM. The fire caused the evacuation of 250 workers and residents from neighborhoods around the facility. Even though the facility had been abandoned for several years, two...


To access the remainder of this piece of premium content, you must be registered with Firehouse. Already have an account? Login

Register in seconds by connecting with your preferred Social Network.

OR

Complete the registration form.

Required
Required
Required
Required
Required
Required
Required
Required
Required
Required

Natural gas supply – The natural gas supply was active and flowing into the building. This was a likely cause of some of the rapid fire spread. The only way to shut it off was by the gas company capping the line because all of the valves were seized and flowing. Never assume utilities to an abandoned building have been turned off.

Firefighter rehabilitation – One firefighter was treated for heat exhaustion. Although firefighter accountability was good, this firefighter was working in an area that required full protective clothing and an airpack. There are a lot of questions with rehab, hydration and fitness of firefighters. Did firefighters pre-hydrate before their shift? Were firefighters hydrating through the course of the incident? Did firefighters rotate too long? Although the firefighter fully recovered, the department is revamping its entire rehabilitation program. A complete overhaul of the firefighter rehab program is underway through the department’s Safety Committee and Local 244.

Fireground control – Combining the rehab area with the command post was a mistake. The command post must be kept separate from all distractions.

Successes

Incident command – The Incident Command System (ICS) and Personnel Accountability System (PAS) were implemented to bring the incident to a successful conclusion.

Water supply – This operation was a testament to the driver/engineer program and good training. The department has been proficient through the years with rural water supply and drafting operations, and maintains that proficiency through its driver/engineer program. The Training and Special Operations Division has consolidated multiple drop tanks, jet siphons and other needed equipment to create a “big water” unit.

Going defensive – The initial crews made a difficult decision. Credit that to good training and the unfortunate lessons learned from the Dec. 3. 1999 cold-storage warehouse fire in Worcester, MA, in which six firefighters were killed (see the March 2000 issue of Firehouse® for complete coverage of the fire and its aftermath).

Collapse zones – The building imploded. Although firefighters prepared for an ugly collapse, the building fell in on itself. Firefighters respected the collapse zones and operated as close to the corners as possible.

Handling hazardous materials – Anhydrous ammonia was a problem. The manner in which it was handled was also one of the incident’s greatest successes. The department is in the process of improving its air-monitoring equipment and corresponding standard operating guidelines (SOGs). The department is also improving its relationship and training with the 64th CST with more comprehensive training planned. Hazmat operations and air-monitoring procedures are under review.