The Apparatus Architect

The November installment of The Apparatus Architect reviewed some history regarding fire apparatus cab design and the impact of staffing on seating positions and arrangements. Over the years, with the advent of four-door-cab apparatus, more seating and...


To access the remainder of this piece of premium content, you must be registered with Firehouse. Already have an account? Login

Register in seconds by connecting with your preferred Social Network.

OR

Complete the registration form.

Required
Required
Required
Required
Required
Required
Required
Required
Required
Required

Safety measures sometimes come in small areas, such as location of dashboard instruments, emergency warning light controls, hazard indicators and other components. The Dash CF enjoys a logical arrangement of controls for the driver, particularly the position of the accelerator and brake pedals, which have been problematic in some apparatus designs in the past. The floor area between the driver and officer’s seats is open across the full width of the cab with the forward portion of the engine cover providing a logical mounting location for map books and other resource materials.

With the engine located in the rear of the cab, two seats are provided on each side, one forward and one rear facing, each equipped to hold self-contained breathing apparatus (SCBA). The engine box area measures 39 inches wide by 83 inches long and sits 23 inches above the level of the floor. The top, flat surface is a natural area to mount equipment such as handlights, portable radios and irons. With a ceiling height of 61 inches in the front of the cab and 70 inches in the crew area, there is adequate room for personnel to safely egress these areas.

 

Equipment Storage

There are more than several schools of thought regarding the amount of equipment storage that should be permitted inside the cab. For those few departments that feel they need more than six seating positions, the available space remaining inside the crew area is very limited and by the time you mount a hand light and portable radio for each member there is no open area left for hand tools and equipment. This is where department standard operating guidelines (SOGs) and training come into play. Depending on your staffing and response patterns, each seat on the apparatus should have a riding assignment to detail the specific job functions that each firefighter is responsible for, including tools and equipment that each should carry and be responsible for at the scene of the incident.

The Pierce Dash CF provides more than sufficient room inside the cab to carry those essential pieces of equipment that a battle-ready firefighter would need immediately on exiting the cab. Safety is a mindset that all fire departments should strive to instill with their personnel when operating on apparatus and at the scene of any incident. The engineers at Pierce have a done a creditable job to assess many of the current problems with cab design and safety in addition to bringing about a reality check with respect to the size and overall length of a practical piece of fire apparatus.

With the cost of new apparatus, down time and maintenance costs becoming more of an issue, particularly where departments do not have their own shops or repair facilities, several maintenance-friendly features have been incorporated into the Dash CF. These include a drop-down panel on the officer’s side of the cab that permits access to electrical components, battery charges and windshield-wiper motors. Fluid checks and fills for the engine and transmission are through a hinged access door at the left-side crew-cab door with chassis filters all at one location outside of the frame rails. The chassis batteries are protected inside of the frame with ready access to the alternator and air cleaner.

With the number of innovations on the Pierce Dash CF chassis, there will be some skeptics who are critical of the concepts and designs put forth with this unit. Many times we have heard the term to describe the fire service as “200 years of tradition unimpeded by progress.” Since the first steamer was introduced back in 1854, the fire service with few exceptions has been slow to universally accept new technology in many areas. Consider that while metal, hydraulically raised aerial ladders were developed in 1935, many departments continued to prefer wooden, spring-raised aerial ladders, which were built by several manufacturers until 1955.

For many years, the cab-forward design was the predominant product available to the fire service. Departments across the United States used this type of custom cab to provide seating for four personnel and any additional members had to ride on the back step or were exposed in the jump-seat area. Safety concerns, together with demographic changes in the inner cities, created a new era of cab designs to provide enclosed seating areas for all personnel. These changes, together with market-driven innovations such as the Pierce Dash CF, should provide a number of positive choices for fire departments to consider when specifying new apparatus for their fleets.