Extinguishing Chimney Fires With Positive Pressure Ventilation

Dec. 1, 1998
Extinguishing a working chimney fire with PPV and a dry chemical extinguisher is a relatively easy task to perform. It eliminates the need for placing personnel in harms way with extended roof operations, especially during periods of inclement weather. Session Reference: 1 Topic: Basic Firefighting: Extinguishing Chimney Fires With Positive Pressure Ventilation Level of Instruction: 3 Time Required: 2-3 Hours

Extinguishing a working chimney fire with PPV and a dry chemical extinguisher is a relatively easy task to perform. It eliminates the need for placing personnel in harms way with extended roof operations, especially during periods of inclement weather.

Session Reference: 1

Topic: Basic Firefighting: Extinguishing Chimney Fires With Positive Pressure Ventilation

Level of Instruction: 3

Time Required: 2-3 Hours

Learning/Teaching Aids:

• Electric powered PPV blower or gas-powered blower

• A minimum 21-24" in diameter (shroud) for optimal ventilation

• Dry chemical extinguisher

• An acquired structure with chimney intact or training center structural building with chimney area

• Streamers and theatrical smoke generator (optional) if an acquired structure is not available]

• If PPV blowers not available, use smoke ejectors stacked and reverse direction

• Fire department pumper equipped with structural firefighting hose-lines and a water source

Behaviors to Foster:

• Understand the reasoning behind not placing personnel on a pitched roof during periods of inclement weather to extinguish chimney fires.

• Understand the process of chimney fire extinguishment using PPV and a dry chemical extinguisher.

• Understand that PPV will not extend chimney fire into uninvolved portions of the structure if traditional firefighting activities are conducted in conjunction with this technique.

Task: The student will be able to extinguish a chimney fire on a structure with a pitched roof, functioning as a member of a team.

Given: A structure with a chimney, pitched roof, a dry chemical extinguisher, a PPV blower, appropriate fire suppression apparatus, and a supervising officer.

Standard: So that personnel are eliminated from roof activities, a working chimney fire is effectively extinguished using PPV and a dry chemical extinguisher, and any potential for fire spread through fractures/breaches in the flue system is prevented and held in check.

Prerequisite Knowledge:

• Chimney construction

• PPV blowers and positive pressure ventilation tactics

• Firefighting strategies for interior attack

• Dry chemical extinguishers

• Fire spread/behavior

Prerequisite Skills:

• Ability to relate extinguishment strategies to chimney fire scenarios

• Ability to teach before an audience - verbally and in written format

• Ability to direct the extinguishment efforts of a team assigned to interior operations

• Ability to determine potential paths for fire spread

• Ability to stop any potential fire spread from a chimney fire into the actual structure

Preparation

Motivation: Extinguishing a working chimney fire with PPV and a dry chemical extinguisher is a relatively easy task to perform. It eliminates the need for placing personnel in harms way with extended roof operations, especially during periods of inclement weather. Typical chimney fire operations take between 1-11/2 hours to mitigate. PPV and a dry chemical extinguisher will cut the extinguishment activity to 10-15 minutes because it is much less labor intensive.

Objective (SPO): The student will function as a member of an interior attack team, will extinguish a chimney fire using positive pressure ventilation, a dry chemical extinguisher, and the required hoselines in place from a fire department pumper to the satisfaction of the instructor.

Overview: Basic Firefighting: Extinguishing Chimney Fires With Positive Pressure Ventilation

• Chimney Construction Features

• Extinguishment

• Check for Extension

Basic Firefighting: Extinguishing Chimney Fires With Positive Pressure Ventilation

SPO 1-1 The student will function as a member of an interior attack team, will extinguish a chimney fire using positive pressure ventilation, a dry chemical extinguisher, and the required hoselines in place from a fire department pumper to the satisfaction of the instructor.

EO 1-1 Identify the characteristics of standard chimney construction and its relation to the interior/exterior of a structure.

EO 1-2 Apply the steps required to successfully extinguish a working chimney fire using PPV and a dry chemical extinguisher.

EO 1-3 Check for and prevent possible fire extension into an uninvolved structure during PPV operations.

Instructional Guide

Opener: Call to order; start with a motivator (need to know) related to objectives; state objectives and main points.

I. Chimney Construction Features (1-1)

Masonry

• Solid/waterproof modular concrete block, lined with a fire clay flue or fire clay brick

• Uses refractory cement mixture to join brick and flue lining

• Two-three inches is the rule of thumb air space clearance between the interior masonry chimneys and combustible material

Metal

• Single-wall metal chimney or unlisted metal shall not be used inside or outside one and two story single family dwellings

• May be used on a residential type or low heat appliance such as a pellet stove

• Must be properly riveted, welded, or bolted, and properly secured to the structure

• Must also have the proper clearance from structure to prevent pyrolysis

Factory built (zero clearance)

• Pre-engineered and designed to function as a unit

• Manufacturer provides a special starter section that locks into the collar at the top of the fireplace

• When passing through combustible material, a fire stop spacer must be used as specified by the manufacturer

Replacement (re-lining)

• Consists of rigid and flexible stainless steel

• Is placed inside of an existing flue, and surrounded by noncombustible insulations

Fireplaces consist of:

• Cap

• Flue

• Mantel

• Smoke Dome

• Smoke shelf

• Damper

• Facing

• Throat

• Lintel

• Firebox

• Hearth

• Ash pit

• Foundation

II. Extinguishment (1-2)

• Conduct a size-up in accordance with established SOPs (AHJ)

• Conduct interior size-up of fireplace and upper/lower floor space in structure

• Advance attack lines into first floor and upper floor(s) as directed and standby

• If interior environment is smoke filled, monitor air samples for CO levels and don SCBA

• Remove contents from firebox and extinguish outside of structure with water

• Place PPV blower at appropriate door nearest fireplace and close off the rest of the house or door isolating fireplace room from rest of structure

• Start up blower and run at 1/2 to full rpm as required to facilitate chimney drafting

• Place dry chemical extinguisher hose in fireplace

• Aiming it up the flue opening

• Discharge the product in 1-2 second bursts

• Be careful not to prolong this process as the product will be heavy and fall back down into the firebox area

• Monitor the drafting process while discharging the extinguisher

• Place a spotter outside the structure to monitor product egress from the top of the chimney cap area

III. Check for Extension (1-1-2)

Send attack crews to upper floors and attic areas with charged hoselines, to ensure that extension has not occurred (Use 11/2 - 13/4" hoselines)

• No booster lines

• No PW cans

• Use a mirror device to check for flue extinguishment

• Advise homeowner to have a professional chimney company come out to perform an inspection before it is used again

• Do not forget to clean up the mess before leaving a structure

Summary

Basic Firefighting: Extinguishing Chimney Fires With Positive Pressure Ventilation

• Chimney Construction Features

• Extinguishment

• Check for Extension

Oral Review: Under each review point, recall and list three features from the discussion. Make a note of these points or highlight points in your notes so you may use them for exam review.